The new testo 310 combines simple functions with a high level of measurement accuracy, and is thus perfect for all basic measurements on heating systems.
Long battery lifetimes of up to 10 hours guarantee you high availability. Its easy handling and compact design make it a robust tool for daily work – even when things get rough. The printer specially developed for the testo 310, including infrared interface, allows you to easily create clear reports on site.
Technical Data
MEASURING RANGE |
ACCURACY ±1 DIGIT |
RESOLUTION |
ADJUSTMENT
|
|
TEMPERATURE (FLUE GAS) |
0.0 TO 400.0 °C |
±1 °C (0,0 TO 100,0 °C)±1.5 % OF READING ( > 100 °C) |
0.1 °C |
< 50 SEC |
TEMPERATURE (AMBIENT TEMPERATURE) |
-20 TO +100.0 °C |
± 1 °C |
0.1 °C |
< 50 SEC |
DRAUGHT MEASUREMENT |
-20.00 TO +20,00 HPA |
± 0.03 HPA (-3.00 TO +500 HPA)± 1.5% OF M.V. (REMAINING RANGE) |
0.01 HPA |
|
PRESS. MEASUREMENT |
-40,00 TO +40.0 HPA |
± 0.5 HPA |
0.1 HPA |
|
O2 MEASUREMENT |
0,0 TO 21.0 VOL.% |
± 0.2 VOL.% |
0.1 VOL. % |
30 SEC |
CO MEASUREMENT (WITHOUT
|
0 TO 4000 PPM |
±20 PPM (0 TO 400 PPM)±1,5 % OF READING (401 TO 2000 PPM)±10 % OF READING (2001 TO 4000 PPM) |
1 PPM |
60 SEC |
AMBIENT CO MEASUREMENT |
0 TO 4000 PPM |
±20 PPM (0 - 400 PPM)±1,5 % OF READING (401 TO 2000 PPM)±10 % OF READING (2001 TO 4000 PPM) |
1 PPM |
60 SEC |
DETERMINATION DEGREE OF EFFECTIVITY (ETA) |
0 TO 120 % |
0.1 % |
||
EXHAUST GAS LOSS |
0 TO 99,9 % |
0.1 % |
||
GENERAL TECHNICAL DATA |
||||
STORAGE TEMP. |
-20.0 °C TO +50,0 °C |
|||
OPER. TEMP. |
-5 TO +45 °C |
|||
POWER SUPPLY |
RECH. BATT.: 1500 MAH, MAINS UNIT 5V / 1A |
|||
MEMORY |
NO MEMORY |
|||
DISPLAY |
BACKLIT 2-LINE DISPLAY |
|||
WEIGHT (WITH PROBE) |
APPROX. 700 G |
|||
DIMENSIONS |
201 X 83 X 44 MM |