Fluke 353 True-rms 2000 A Clamp Meter

Confidently take reliable readings with the True-rms, Fluke 353 digital clamp meter; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads.

Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
The large 58 mm ( 2.3 in) jaw capacity is suitable for large or multiple conductors
CAT IV 600 V, CAT III 1000 V rating for added user protection
In-rush current measurement captures ‘ power-on’ surge current with accuracy and repeatability
Accurately measure frequency up to 1 kHz for optimum troubleshooting
Quickly analyze readings using the MIN, MAX, and AVG functions
A large backlit display allows for easy visibility in low-lit areas
Use the display hold feature to capture readings even when the display cannot be viewed
Use the low-pass filter to smooth out noisy loads and stabilize readings

Electrical Specifications
Current measurement dc and ac 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A; 1400 ac rms
Resolution 10 mA / 100 mA / 1 A
Accuracy A: 1.5 % rdg + 15 digits
A: 1.5 % rdg + 5 digits
Trigger Level for Inrush 0.50 A / 5.0 A / 5 A
Trigger Level for Hz Filter OFF 2.50 A / 2.5 A / 8 A
Trigger Level for Hz Filter ON 0.50 A / 2.5 A / 8 A
Crest Factor ( 50/ 60 Hz) Range 40 A / 400 A / 2000 A; 1400 ac rms
Crest Factor* 2 @ 33 A, 2.4 @ 27 A
2 @ 330 A, 2.4 @ 270 A
2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 ac rms
Resolution 10 mA / 100 mA / 1 A
Accuracy 10 A : 3.5 % rdg + 15 digits
10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush 0.50 A / 5.0 A / 5 A
Trigger Level for Hz Filter OFF 2.50 A / 2.5 A / 8 A
Trigger Level for Hz Filter ON 0.50 A / 2.5 A / 8 A
Frequency measurement Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz ( 15 Hz to 399.9 Hz) ; 1 Hz ( 400 Hz to 1 kHz) 
Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables

* Add 2 % to error spec for CF > 2
General Specifications
Batteries Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life ( with typical usage, backlight off) 100 hours
Test leads Rated to 1000 V
Weight .814 kg ( 1.8 lb) 
Jaw size 58 mm ( 2.28 in) 
Dimensions ( LxWxD) 300 mm x 98 mm x 52 mm ( 12 in x 3.75 in x 2 in) 
Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental Specifications
Operating temperature 32 ° F to + 122 ° F ( 0 ° C to + 50 ° C) 
Storage temperature -4 ° F to 140 ° F ( -20 ° C to + 60 ° C) 
Operating humidity 0 to 95 % ( non-condensing) 
Operating altitude 2000 m
Storage altitude 10, 000 m
IP rating 42 ( indoor use only) 
Drop test requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/ EN 61326-1: 1997 class B
IEC/ EN 61326: 1997 3V/ m, performance criteria B, EN61325
Temperature coefficients Current 0.1 % of reading per ° C outside 22 ° C to 24 ° C
Voltage 0.1 % of reading per ° C outside 22 ° C to 24 ° C