• Smallest clamp meter capable of AC and DC current measurements.
• 300A auto ranging has minimum resolu-tion of 0.01A AC/ DC.
• Auto-zero function to allow one touch zero adjustment.
AC A 40/ 300A ± 1% rdg± 4dgt [ 50/ 60Hz] ( 0~ 40A)
| ± 2.5% rdg± 4dgt [ 20Hz~ 1kHz] ( 0~ 40A)
| ± 1.5% rdg± 4dgt [ 50/ 60Hz] ( 20~ 200A)
| ± 2.5% rdg± 4dgt [ 20Hz~ 1kHz] ( 20~ 200A)
| ± 3.5% rdg [ 50/ 60Hz] ( 200~ 300A)
| ± 4% rdg [ 20Hz~ 1kHz] ( 200~ 300A)
DC A 40/ 300A
| ± 1% rdg± 4dgt ( 0~ ± 40A)
| ± 1.5% rdg± 4dgt ( ± 20~ ± 200A)
| ± 3% rdg ( ± 200~ ± 300A)
Conductor Size Ø 24mm max.
Safety Standard IEC 61010-1CAT.III 300V
IEC 61010-2-032
Frequency Response DC, 20Hz~ 1kHz
Withstand Voltage 3700V AC for 1 minute
Power Source LR-44 ( 1.5V) × 2
Dimensions 147( L) × 59( W) × 25( D) mm
Weight 100g approx.
Accessories 9090 ( Carrying Case)
LR-44 × 2
Instruction Manual
Optional 8008 ( Multi-Tran) ( AC only)
==============================
Untuk Info dan Pemesanan Hubungi :
DARMATEK
Contact person : Subarkah
Telp/ Fax : 021-71031268
H P : 081283804273/ 085774067221
email : subarkah18@ yahoo.co.id
Gmail : darmatek1@ gmail.com
Y M : cs_darmatek
Pin BB : 7512CBB7