The PSC-4010 is a superior loop calibrator with voltage, current, and frequency functions. With the best display in the business it makes the essentials of instrument calibration easier than ever. Need to punch in direct value rapidly, not a problem with the PSC-4010. It has a full numeric keypad. And, a bonus feature not found in other loop calibrators is frequency in and out. The calibrator has the following features and functions:
- A graphics display. The display can be used to source and measure volts, current, frequency, and to source pulse trains.
- Setpoints in each range for quickly increasing/decreasing output
- An interactive menu
- Complete serial interface for remote control
Features :
- Multifunction Loop & Frequency
- ClearbriteTM Graphic Display
- Auto Stepping
- Auto Ramping
- RS-232 Serial Interface
- NIST Calibration Certificate
- Rubber Boot
- Martel 3-Key User Interface
- Scroll/Step Output
- Numeric Input
- AC Charger/Adapter Option
Specifications (All specifications apply at 23 °C ± 5°C unless otherwise stated. Outside this range add ±0.005% of reading/°C. Accuracy is % of reading ± floor spec.)
General Specifications (10 Series)
|
|
Operating Temperature |
-10 °C to 50 °C |
Storage Temperature |
-20 °C to 70 °C |
Power |
4 AA Alkaline or optional rechargeable batteries |
Low Battery Warning |
Yes, on display |
ClearBrite™ Display |
High contrast 128 x 64 pixel addressable graphic LCD w backlight
2.4" x 1.8" (63 mm x 44 mm) |
Serial Communications |
Yes, ASCII, RS-232, requires optional 1919069 serial cable or 1919896 USB cable |
CE-EMC |
EN50082-1 and EN55022: 1994 Class B |
Safety |
CSA C22.2 No. 1010-1: 1992 |
Weight |
1.8 lb (0.82 kg) |
Size |
8.5" x 4.8" x 2.1" (22 cm x 12 cm x 5.3 cm) |
Other |
IP54
Protected against misconnection to 250 VAC/VDC |
DC Voltage & Current Measure/Source
Note: optional 50 mA range available |
|
|
|
|
|
DC Voltage Lower Non-Isolated Measure |
DC Voltage Lower Non-Isolated Source |
DC Current Lower Isolated Measurement |
DC Current Lower Isolated Source |
Range |
0.000V - 20.000V |
0.000V - 20.000V |
0.000 mA - 24.000 mA |
0.000 mA - 24.000 mA |
Accuracy |
0.015% ± 2 mV |
0.015% ± 2 mV |
0.015% ± 2 uA |
0.015% ± 2 uA |
Frequency Measure/Source
|
|
|
|
|
|
|
|
Frequency Measurement |
Frequency Source |
Frequency Measurement |
Frequency Source |
Frequency Measurement |
Frequency Source |
Range |
2.0 CPM - 600.0 CPM |
2.0 CPM - 600.0 CPM |
1.0 Hz - 1000.0 Hz |
1.0 Hz - 1000.0 Hz |
1.00 kHz - 10.00 kHz |
1.00 kHz - 10.00 kHz |
Accuracy |
0.05% ± 0.1 CPM |
0.05% |
0.05% ± 0.1 Hz |
0.05% |
0.05% ± 0.01 kHz |
0.05% |
MilliVolts Measure/Source
|
Millivolts Measure |
Millivolts Source |
Range |
0.000 mV - 90.000 mV |
0.000 mV - 100.000 mV |
Accuracy |
0.02% ± 10 uV |
0.02% ± 10 uV |