- Full scale accuracy on all pressure ranges of ±0.05% FS
- Temperature compensation ensure accuracy in the field with no effect over 18°C to 23°C
- Standard available ranges – 1, 5, 30, 100, or 300 psi
- 4-20 mA measurement input
- DC Voltage measurement 0-30 V
- Internal 24 V Loop Power Supply
- Displays in 16 standard engineering units plus one user-defined
- Large graphic LCD with backlight that can be configured to display 3 inputs simultaneously
- External pressure module connection supports all BetaPort-P pressure modules
- Switch test on pressure (internal or external)
- Up to five frequently setup can be stored; last setup recalled on power-up
- % Error and damping functions
Specifications (18°C to 28°C, unless otherwise noted)
Media Compatibility | ||
---|---|---|
Clean dry air or gas only | ||
Engineering Units | ||
psi, bar, mbar, kPa, kg/cm2, cmH2O@4°C, cmH2O@20°C, mmH2O@4°C, mmH2O@20°C, inH2O@4°C, inH2O@20°C, inH2O@60°F, mmHg@0°C, inHg@0°C, MPa, FT H2O@60°C plus 1 custom at time of order | ||
Accuracy | ||
Pressure | ||
All ranges | ±0.05 % FS | |
mA | ±0.015% of reading ±0.002mA | |
Volts | ±0.015% of reading ±0.002V | |
Temperature Effect | ||
No effect on accuracy on all functions from 18°C to 23°C | ||
General | ||
Instrument Setup Recall 5; last used on power-up | ||
Environmental | ||
Operating Temperature | -10 °C to +50 °C | |
Storage Temperature | -20 °C to +60 °C | |
Power Requirements | 6.0 VDC | |
Battery | Four (4) standard AA cells | |
Battery Life | >35 hours, typical usage | |
Physical | ||
Dimensions | 8.3” H x 3.9”W x 1.8”D (21.082 x 9.906 x 4.572 cm) |
|
Weight | 1 lbs, 4 oz. (0.567 kg) | |
Connectors/Ports Pressure | ||
One, 1/8” NPT Two, std banana jacks |
||
External BetaPort-P pressure module; |