FEATURES : 
Telescopic, compact, light-weight : Length : from 230mm to 880mm. Weight : Approx. 155g
High-voltage detectable : The equipment, whether in stretched state is  available for voltage detection in high-tension circuits ( 3.3kV, 6.6kV  and 24kV) whether the wires involved are naked or insulated.
Low-voltage detectable : The equipment can be used for voltage  detection in low-tension circuits ( 80V ~ 600V) by holding the nameplate  portion of the detecting head. Before-use check can easily be done by  plugging in an AC 100V plug socket, without using a tester.
Easy to recognize indication : Intermittent lighting in red of a high  intensity light-emitting diode and intermittent audible sound of an  electronic buzzer are readily recongnizable at a full daylight, noisy  location.
Waterproof : The detecting head, being tightly enclosed, is free from any trouble due to dust, dirt, water or the like.
Dielectric strength : 
( a) Between Sensing tip ~ Grip portion : 50kVAC, 1 min ( The detector has to be stretched) .
( b) Between Sensing tip ~ Nameplate portion : 4kV AC, 1 min.
Construction : Waterproof ( detecting head impervious to water) .
Insulation resistance : Measure the insulation resistance with the high  voltage insulation tester. The areas we measure are the same as  dielectric strength test.
( a) Between Sensing tip ~ Grip portion : 1kV ( The detector has to be  stretched) . The insulation resistance has to be more than 2000M Ohm.
( b) Between Sensing tip ~ Nameplate portion : 1kV. The insulation resistance has to be more than 2000M Ohm.
Leakage current test : Put high voltage on the parts listed below.
( a) Between Sensing tip ~ Grip portion : 50kV AC, 1 min ( The detector  has to be stretched) . The leakage current has to be 100uA or less than  100uA.
( b) Between Sensing tip ~ Nameplate portion : 4kV AC, 1 min. The leakage current has to be 100uA or less than 100uA
Meets EN 61010-1, EN50081-1, EN 55082-1, EN 55022, EN 61000-4-2, EN 61000-4-3
This model 276 HD detects the presence of voltage in AC lines. An  elongate insulation rod permits checking of high tension circuits at  safe distance for voltage.
The equipment is compact, light weight, and easy to handle, and is also  available for voltage detection in low-tension circuits.
SPECIFICATIONS
Working Voltage Range H.V. : 3kV ~ 24kV AC ...... hold grip portion to detect.
L.V. : 80V ~ 600V AC ...... hold anmeplate portion to detect.
Frequency 50Hz / 60Hz
Operation Test ( Initial voltage) ( a) When stretched, hold the grip  portion. Put the sensing tip in contact with the voltage : 250V AC + / -  50V the LED and buzzer should work.
( b) When retracted, hold the nameplate portion. Put the sensing tip in  contact with the voltage : 80V AC or below the LED and buzzer should  work.
Operation start distance Distance at which operation starts when front  metal is brought near dia. 5mm O.C. wire with grip portion meld by hand.
Where 24kV / dia. 3mm ( voltage to ground) ...... abt 20 cm.
Where 6.6kV / dia. 3mm ( voltage to ground) ...... abt 3 cm.
Where 3.3kV / dia. 3mm ( voltage to ground) ...... abt 1 cm.
Woking temperature rang -10 degree C ~ + 50 degree C
Battery 2 button-cells LR44 ( 1.5V) 
= = = = = = = = = = = = = = = = = = = = = = = = =
Untuk Info dan Pemesanan Hubungi : 
DARMATEK
Contact : Subarkah
Telpon : 021-71031268
WA : 081932632003
H P : 081283804273/ 085774067221
Email : subarkah18@ yahoo.co.id
Gmail : darmatek1@ gmail.com
Pin BB : D2A771BD
Web : http://www.darmatek.net
Link : http://darmatek.produkanda.co.id
http://darmatek01.blogspot.com